Basler-electric BE1-851 Modbus Protocol Manuel d'utilisateur Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 70
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
2-14 BE1-851 Modbus Protocol 9289900992 Rev F
Holding Read/Write Data
Register Parameter Supported Format Notes
44621-22 Peak Demand Current - Neg-Seq R W DP LEG
44623 Peak Demand Current - Day R - INT TS,LEG
44624-25 Peak Demand Current - Millisecond R - DP TS,LEG
44631-32 Today’s Peak Demand Current - Phase A R W DP LEG
44633 Today’s Peak Demand Current - Day R - INT TS,LEG
44634-35 Today’s Peak Demand Current - Millisecond R - DP TS,LEG
44636-37 Today’s Peak Demand Current - Phase B R W DP LEG
44638 Today’s Peak Demand Current - Day R - INT TS,LEG
44639-40 Today’s Peak Demand Current - Millisecond R - DP TS,LEG
44641-42 Today’s Peak Demand Current - Phase C R W DP LEG
44643 Today’s Peak Demand Current - Day R - INT TS,LEG
44644-45 Today’s Peak Demand Current - Millisecond R - DP TS,LEG
44646-47 Today’s Peak Demand Current - Neutral R W DP LEG
44648 Today’s Peak Demand Current - Day R - INT TS,LEG
44649-50 Today’s Peak Demand Current - Millisecond R - DP TS,LEG
44651-52 Today’s Peak Demand Current - Neg-Seq R W DP LEG
44653 Today’s Peak Demand Current - Day R - INT TS,LEG
44654-55 Today’s Peak Demand Current - Millisecond R - DP TS,LEG
44661-62 Yesterday’s Peak Demand Current - Phase A R W DP LEG
44663 Yesterday’s Peak Demand Current - Day R - INT TS,LEG
44664-65 Yesterday’s Peak Demand Current - Millisecond R - DP TS,LEG
44666-67 Yesterday’s Peak Demand Current - Phase B R W DP LEG
44668 Yesterday’s Peak Demand Current - Day R - INT TS,LEG
44669-70 Yesterday’s Peak Demand Current - Millisecond R - DP TS,LEG
44671-72 Yesterday’s Peak Demand Current - Phase C R W DP LEG
44673 Yesterday’s Peak Demand Current - Day R - INT TS,LEG
44674-75 Yesterday’s Peak Demand Current - Millisecond R - DP TS,LEG
44676-77 Yesterday’s Peak Demand Current - Neutral R W DP LEG
44678 Yesterday’s Peak Demand Current - Day R - INT TS,LEG
44679-80 Yesterday’s Peak Demand Current - Millisecond R - DP TS,LEG
44681-82 Yesterday’s Peak Demand Current - Neg-Seq R W DP LEG
44683 Yesterday’s Peak Demand Current - Day R - INT TS,LEG
44684-85 Yesterday’s Peak Demand Current - Millisecond R - DP TS,LEG
45601-02 General Status R - BM(32) LEG
45603-04 Diagnostic Alarm Status R - BM(32) LEG
45605-06 Major Alarm Status R - BM(32) LEG
45607-08 Minor Alarm Status R - BM(32) LEG
45609-12 System Status R - BM(64) LEG
45617 Hardware Output Status R - BM(16) LEG
45618 Active Setting Group R - INT LEG
45619 Active Logic R - INT LEG
45620 Recloser Status R - BM(16) LEG
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 69 70

Commentaires sur ces manuels

Pas de commentaire